Wednesday, July 8, 2015

Brinks/Broadview Smoke Detector Installation

Adding or Replacing a Fire Alarm

When adding a smoke detector on a Brinks or Broadview system be sure to wire the high side and low side of a 2112i3 smoke detector in the same order as it was wired in the panel. Also be sure to place the resistor in the field at the EOL for proper reporting. After you've installed the smoke detector connect your programmer and go to standard programming to add the zone. Here you will enable the zone and choose the zone type as fire. After that go to advance programming and choose account, here you will build your timer test. Please make sure you start with account 1 as your timer reporting account.

When replacing a smoke detector with a 2112i3 you should be able to swap without any additional programming. If you are swapping a single smoke detector any 4 wire System Sensor/DSC smoke detector will work as a replacement. If you have multiple smoke detectors on a single zone then you will need to get a similar smoke or replace all smokes. The DSC smoke will not work in line with the BV smoke.




Wednesday, June 24, 2015

Trouble with 6280WADT or 6280SADT?

 

Custom Touch Screen Keypads For ADT 6280ADT Systems 



6280WADT & 6280SADT Keypad Software Upgrade
The Latest Software Upgrade for the 6280 Keypad is: 4.1.54
Current Upgrade Posted: 05/18/2015
 
 
Instructions: How to Save Software on SD Card and Update Software on 6280 Keypad
Controller
1. Insert a blank SD card into your device drive so you can download the software onto the
SD card

2. Click on the DOWNLOAD button above and click on Save
 
3. Once saved, double click 6280_V04.1.54.exe. Extract files to your desktop, or to a directory
of your choice. Once the files are extracted, copy them to the SD card, or extract all files from
6280_V04.1.54.exe directly to the SD card. ALL THE BELOW FILES MUST APPEAR ON
THE ROOT OF THE SD CARD FOR THE UPDATE TO BE SUCCESSFUL
 
4. Take the SD card with the software downloaded and insert it into the slot on upper right side
 of the 6280 Keypad. You will hear a snap when the SD card is inserted correctly.
 (For help locating the SD card slot refer to the image below).
 
5.Now take a paper clip and push in the reset button located on the lower right side of the
keypad. (The Reset button is directly behind the “Message LED on the right side of the plastic.
(For help locating the Reset button refer to the image below).
Once pressed the 6280 Keypad will update the new software. You will see the system/display
reboot which will take about 1 minute.

A message on the screen will appear stating, “REMOVE THE SD CARD AND PRESS OK
TO RESET KEYPAD”. Press ok and your keypad will reboot. As soon as the display comes up
the software update will be complete.

     
    If you don't have a paper clip you can use the tools icon + advanced + reset keypad.

Tuesday, June 9, 2015

5834-4 HIGH SECURITY MODE KEYFOB


 
 
Programming
  • Each 5834-4 transmitter has two unique serial numbers assigned during Loop Numbers for the 5834-4 Buttons manufacture.Each button on the unit also has a distinct "loop" number (refer to the Loop Number at right) that you must program into the control panel during installation.
  • Assign each button to an individual zone and designate the Input Type as "BR" (Button Type).
  • When prompted for the serial number, press and release the appropriate button(s) twice, or, manually enter the serial number at the keypad.
NOTE: Serial #2 is one (1) digit higher than serial #1, which is printed on the rear of the transmitter.
                                                                    Hand Model Cliff S.
USING HIGH SECURITY MODE IN COMPATIBLE RECEIVERS AND LOCALLY IN AN RF KEYPAD (eg., 6150RF) 
If used with LYNXR/Quick Connect Series controls earlier than Revision 13.1, Standard Mode must be selected. First select High Security mode, then activate it. Activation syncs the key fob with the security system.
  • 1. Select High Security mode: Mode Simultaneously hold down for 5 secs… A - C - D (LED flashes Red when transmitting) High-Security B - C - D (LED flashes Green when transmitting) Standard
  • 2. Activate High Security mode: • if the key fob is enrolled into the panel, put the security system into Go/No Go Mode 
  • 3. If the key fob is enrolled locally into a 6150RF, go to Step 3 of 6150RF “Programming WITH Local Wireless Keys”, then press the appropriate set of buttons as follows: Serial Number Simultaneously hold down until beeps sound… A - B - C buttons (system beeps twice to confirm) 1 A - B - D buttons (system beeps twice to confirm)
  •  
    Please see below for instructions provided by our small business team.
    ENTER INSTALLER CODE #8 THEN HOLD ALL THREE BUTTONS (NOT PANIC) AT ONCE AND YOU WILL GET TWO BEEPS. THIS CONCLUDES THE PROGRAMMING

Friday, June 5, 2015

Cheat Sheet For GE Concord Panels


Concord 4 – 4321 (Default)
System Programming: [ 8 ] + [ INSTALLER CODE ] + [ 0 ] [ 0 ]
Select "System Programming"
Security--Global Menu--Downloader Code
Security--Global Menu--Installer Code
Security--Partition1--Account # (repeat/copy for mult partitions)
Security--Partition1--Duress Code (9999)

Phones--CS Phone 1—XXX-XXX-XXXX (repeat/copy for multi partitions)

Phone Options--Global--Auto Phone Test--ON

Timers--Global--Next Phone Test--7
Timers--Global--Phone Test Freq—7 (Weekly)

Reporting--Global--AC Failure--ON
Reporting--Partition1--Duress Option--ON

Sensors--Learn Sensors
Sensors--Sensor Text
Sensors--Delete Sensors (Delete any hardware zones not being used)

To Exit, Select "Exit System Programming"

User Programming: [ 9 ] + [ MASTER USER CODE ]
Set Time/Date
Set Master Code
Set any User Codes

CONCORD System Tests:
COMMUNICATIONS TEST: [ 8 ] + [ MASTER USER CODE ] + [ 2 ]
When the panel completes the test, the system returns to the previous arming level
automatically. If the display continues to show PHONE TEST for 1½ minutes or more, enter [ 1 ] + [ MASTER USER CODE ] and recheck phone connection.

15 min SENSOR TEST: [ 8 ] + [ INSTALLER CODE ] + [ 3 ]
Trip each zone/sensor one at a time. Touchpads (and interior sirens) should sound one short,
high-pitched beep and the display should show the sensor name (or number) and OK.
Press the STATUS button when you think all zones/sensors are tested. The touchpad displays
any untested sensors/zones and touchpad panics. If all sensors/zones and touchpad panics
have been tested, the display shows SENSOR TEST OK.
Exit sensor test [ 1 ] + [INSTALLER CODE ]

REPEAT TESTS FOR MULT PARTITIONS
Turn Partition Security OFF in SECURITY GLOBAL menu, then use 7+4+2 to change partition without using code.
**

Thursday, May 28, 2015

How to tie a proffessional home automation system to a SW3000?

Years ago you would only be able to tie the Honeywell Vista 128 series panel to a third party automation system, but times have changed!! The 4232CBM or HSPIM as we like to call it, allows you to communicate with the new Pulse ready systems. This module will give you access to the panel through the home remote stations allowing status updates, arming, and disarming. You may provide the 9 pin connector for the contractor but do not connect it due to the liability.

When programming the communication device follow the Pulse programming for installation requirements.

Please see devices


Wednesday, May 20, 2015

Pulse Camera Connection

Using Encoders to connect to the analog camera makes it viewable on your ADT Pulse. The NV412A encoder needs to be connected via Ethernet to the ADT Gateway. Since the Gateway only has one device port, you will need to add the ADT Pulse net gear switch for multiple cameras.

There are two scenarios that you would want to use this NV412A. The first is if the customer has an existing Analog camera system already installed and just want to be able to view 1-10 of the existing cameras on the Pulse. This is easy because all you need is the NV412A. One for each camera. The cameras are already installed, wired, and powered. So just install the NV412A.

The second scenario includes adding a DVR. This would require installing the NV412A before the DVR for recording continually instead of clips. Unplug the BNC cable from the DVR and plug it into the NV412A and then plug a new BNC cable from the NV412A output to the DVR input.

See the illustration below for more information on installing Encoders.



Tuesday, May 5, 2015

A910 Trouble? Who doesn't love tips?


Function
Instruction
Description:
Hard Wired System - Optional Wireless Pendant
This Control is down loadable.
Code

Code

Code

Press 4 hold for three seconds, Code, Code

First two digits of the code
Note: Quick arming is optional in programming
#, Single digit zone number(1-6), Code
Note: The zone light that is bypassed will start blinking

#, 9 or Arm and Disarm system
Press 6 hold for three seconds
Note: After the initial key is pressed the keypad will emit three beeps to indicate the chime is on or two beeps to indicate the chime is off
Place system on test
Press 9 for 3 beeps, enter five digit service code, (will disconnect line and send in Service On Prem)(call back if on same line) then enter 1,7,7,#,1,*,*(might disconnect) if so call back and enter *, 9, 9, * to to go "Off Prem". New code should be 1234.


Press 9 hold for three seconds, Master Code, Single digit user (2-6), #, New Code
Note: A long beep will be heard
Press 9 hold for three seconds, Master Code, Single digit user (2-6), #, 0, 0, 0, 0
Note: A long beep will be heard
OR
Press [9] hold for three seconds, [mater code], [1], [0], [#], code(1-6).
Press 9 hold for three seconds, Master Code, 1, #, New Code
Note: A long beep will be heard
Press 9 hold for three seconds, Master Code, 6, #, New Code
Note: A long beep will be heard. Continue with the rest of the process
Press 9 hold for three seconds, Master Code, 7, #, Enter number of uses (1-254), *, *, A long beep will be heard
Codes are four digits in length
Master Code = User 1
User Codes = User 2-4
Duress Code/User Code = User 5
Temporary Code = User 6

Master Code - Arm/Disarm/Bypass/Add Codes/Change Codes/Delete Codes

User Codes - Arm/Disarm/Bypass

Duress Code/User Code - Duress Code - Arm/Disarm/Transmits a duress alarm

Temporary Code/User Code - Arm/Disarm the number of preset times entered under the number of uses when the code was added

Press 9 hold for three seconds, Master Code, 8, #, 0, *
Note: This will transmit the signal immediately

Hold [9] for 3 seconds (3 beeps), enter [Master code] [8] [#] [0-24] [*] sets time to next timer test from 0-24 hrs.

Press 9 hold for three seconds, Master Code, 8, #, Number of hours (1-24), *
Code


Press and hold the Fire button down for three seconds

Press and hold the Police button down for three seconds

Press and hold the Medical button down for three seconds
* Press 9 (Hold for 3 beeps, enter 5 digit service code,(might be cut off as system sends in "On Prem" signal) enter 1,9,7,#,1,*,* (Might be cut off again) Wait 3 seconds then enter *,9,9,* (Off Prem)
* Must place system on test.

*, 9, 9, *
Note: After one hour the times out. The system's buffer will not retain the "SVC OFF PREM" signal past one hour from the time it was originally generated.
Hold [9] for 3 seconds, enter [master code], [8], [#],0, [*]
View/Clear Memory: Hold [3] for 3 seconds. Last zone tripped will show for 8 seconds. [*] to clear memory.
Press 7 hold for three seconds, Code
Note: The back up battery has to be fully recharged before it will reset. If the back up battery has not fully recharged wait a few hours and perform the procedure again.
Press *
·  Bottom to Top: Power Trouble (Transformer is partially unplugged or breaker is off)
·  Top to Bottom: Defective Control Panel
*


Code

*

*

Press & hold the number 7 key for 3 seconds, then User Code. If not, try *,7, 4 digit user code



Code


*


The keypad and control unit are separate.
If trouble light is lit press 2 hold for three seconds to enter diagnostic mode. Zone(s) that lights up will define problem. See chart below:
Zone 1 - AC Power Failure
Zone 2 - Low Battery / Blown Fuse
Zone 3 - Supervisory / Trouble
Zone 4 - Fail to Communicate
Zone 5 - Memory Error
Zone 6 - Missing Keypad(to clear - Hold number 8 for 3 seconds (beeps)then press *)

Trouble?Alarm Lights Flashing Alternately: Enter # + 0 to clear.

Zone Lights Scrolling Top to Bottom = Defective Control
Bottom to Top = Power Out (Transformer partially unplugged, outlet bad, circuit breaker off or GFI tripped) or a wiring problem within the control.
Press 8 hold for three seconds, Activate Sensors
Note: This is a local test no signal will be transmitted to the monitoring station.

*
Utility Output Command: Hold [0] for 3 seconds, enter [User code] Can be programmed by installer to operate mag locks, electric lights, camera's etc. User code must have a configuration digit of 2, 3, 5, or 7 (programmed by installer)