Hard Wired System - Optional
Wireless Pendant
This Control is down loadable. |
|
|
||
Code
Code Code Press 4 hold for three seconds, Code, Code First two digits of the code Note: Quick arming is optional in programming |
||
|
||
#, Single digit zone number(1-6), Code
Note: The zone light that is bypassed will start blinking #, 9 or Arm and Disarm system |
||
|
||
Press 6 hold for three seconds
Note: After the initial key is pressed the keypad will emit three beeps to indicate the chime is on or two beeps to indicate the chime is off |
||
|
||
Place system on test
Press 9 for 3 beeps, enter five digit service code, (will disconnect line and send in Service On Prem)(call back if on same line) then enter 1,7,7,#,1,*,*(might disconnect) if so call back and enter *, 9, 9, * to to go "Off Prem". New code should be 1234. |
||
|
||
Press 9 hold for three seconds, Master Code, Single digit user (2-6), #, New Code Note: A long beep will be heard |
||
|
||
Press 9 hold for three seconds,
Master Code, Single digit user (2-6), #, 0, 0, 0, 0
Note: A long beep will be heard OR Press [9] hold for three seconds, [mater code], [1], [0], [#], code(1-6). |
||
|
||
Press 9 hold for three seconds, Master Code, 1, #, New
Code
Note: A long beep will be heard |
||
|
||
Press 9 hold for three seconds, Master Code, 6, #, New
Code
Note: A long beep will be heard. Continue with the rest of the process Press 9 hold for three seconds, Master Code, 7, #, Enter number of uses (1-254), *, *, A long beep will be heard |
||
|
||
Codes are four digits in length
Master Code = User 1 User Codes = User 2-4 Duress Code/User Code = User 5 Temporary Code = User 6 Master Code - Arm/Disarm/Bypass/Add Codes/Change Codes/Delete Codes User Codes - Arm/Disarm/Bypass Duress Code/User Code - Duress Code - Arm/Disarm/Transmits a duress alarm Temporary Code/User Code - Arm/Disarm the number of preset times entered under the number of uses when the code was added |
||
|
||
Press 9 hold for three seconds, Master Code, 8, #, 0, * Note: This will transmit the signal immediately Hold [9] for 3 seconds (3 beeps), enter [Master code] [8] [#] [0-24] [*] sets time to next timer test from 0-24 hrs. |
||
|
||
Press 9 hold for three seconds, Master Code, 8, #, Number of hours (1-24), * |
||
|
||
Code
|
||
|
||
Press and hold the Fire button down for three seconds Press and hold the Police button down for three seconds Press and hold the Medical button down for three seconds |
||
|
||
* Press 9 (Hold for 3 beeps, enter
5 digit service code,(might be cut off as system sends in "On Prem"
signal) enter 1,9,7,#,1,*,* (Might be cut off again) Wait 3 seconds then
enter *,9,9,* (Off Prem)
* Must place system on test. |
||
|
||
*, 9, 9, * Note: After one hour the times out. The system's buffer will not retain the "SVC OFF PREM" signal past one hour from the time it was originally generated. |
||
|
||
Hold [9] for 3 seconds, enter
[master code], [8], [#],0, [*]
|
||
|
||
View/Clear Memory: Hold [3] for 3
seconds. Last zone tripped will show for 8 seconds. [*] to clear memory.
|
||
|
||
Press 7 hold for three seconds, Code
Note: The back up battery has to be fully recharged before it will reset. If the back up battery has not fully recharged wait a few hours and perform the procedure again. |
||
|
||
Press *
|
||
|
||
· Bottom to Top:
Power Trouble (Transformer is partially unplugged or breaker is off)
· Top to Bottom: Defective
Control Panel
|
||
|
||
*
|
||
|
||
Code * * Press & hold the number 7 key for 3 seconds, then User Code. If not, try *,7, 4 digit user code |
||
|
||
Code * |
||
|
||
The keypad and control unit are separate. |
||
|
||
If trouble light is lit press 2
hold for three seconds to enter diagnostic mode. Zone(s) that lights up will
define problem. See chart below:
Zone 1 - AC Power Failure Zone 2 - Low Battery / Blown Fuse Zone 3 - Supervisory / Trouble Zone 4 - Fail to Communicate Zone 5 - Memory Error Zone 6 - Missing Keypad(to clear - Hold number 8 for 3 seconds (beeps)then press *) Trouble?Alarm Lights Flashing Alternately: Enter # + 0 to clear. Zone Lights Scrolling Top to Bottom = Defective Control Bottom to Top = Power Out (Transformer partially unplugged, outlet bad, circuit breaker off or GFI tripped) or a wiring problem within the control. |
||
|
||
Press 8 hold for three seconds, Activate Sensors
Note: This is a local test no signal will be transmitted to the monitoring station. * |
||
|
||
Utility Output Command: Hold [0]
for 3 seconds, enter [User code] Can be programmed by installer to operate
mag locks, electric lights, camera's etc. User code must have a configuration
digit of 2, 3, 5, or 7 (programmed by installer)
|