Friday, June 5, 2015
Cheat Sheet For GE Concord Panels
Concord 4 – 4321 (Default)
System Programming: [ 8 ] + [ INSTALLER CODE ] + [ 0 ] [ 0 ]
Select "System Programming"
Security--Global Menu--Downloader Code
Security--Global Menu--Installer Code
Security--Partition1--Account # (repeat/copy for mult partitions)
Security--Partition1--Duress Code (9999)
Phones--CS Phone 1—XXX-XXX-XXXX (repeat/copy for multi partitions)
Phone Options--Global--Auto Phone Test--ON
Timers--Global--Next Phone Test--7
Timers--Global--Phone Test Freq—7 (Weekly)
Reporting--Global--AC Failure--ON
Reporting--Partition1--Duress Option--ON
Sensors--Learn Sensors
Sensors--Sensor Text
Sensors--Delete Sensors (Delete any hardware zones not being used)
To Exit, Select "Exit System Programming"
User Programming: [ 9 ] + [ MASTER USER CODE ]
Set Time/Date
Set Master Code
Set any User Codes
CONCORD System Tests:
COMMUNICATIONS TEST: [ 8 ] + [ MASTER USER CODE ] + [ 2 ]
When the panel completes the test, the system returns to the previous arming level
automatically. If the display continues to show PHONE TEST for 1½ minutes or more, enter [ 1 ] + [ MASTER USER CODE ] and recheck phone connection.
15 min SENSOR TEST: [ 8 ] + [ INSTALLER CODE ] + [ 3 ]
Trip each zone/sensor one at a time. Touchpads (and interior sirens) should sound one short,
high-pitched beep and the display should show the sensor name (or number) and OK.
Press the STATUS button when you think all zones/sensors are tested. The touchpad displays
any untested sensors/zones and touchpad panics. If all sensors/zones and touchpad panics
have been tested, the display shows SENSOR TEST OK.
Exit sensor test [ 1 ] + [INSTALLER CODE ]
REPEAT TESTS FOR MULT PARTITIONS
Turn Partition Security OFF in SECURITY GLOBAL menu, then use 7+4+2 to change partition without using code.
**
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment