Wednesday, June 24, 2015

Trouble with 6280WADT or 6280SADT?

 

Custom Touch Screen Keypads For ADT 6280ADT Systems 



6280WADT & 6280SADT Keypad Software Upgrade
The Latest Software Upgrade for the 6280 Keypad is: 4.1.54
Current Upgrade Posted: 05/18/2015
 
 
Instructions: How to Save Software on SD Card and Update Software on 6280 Keypad
Controller
1. Insert a blank SD card into your device drive so you can download the software onto the
SD card

2. Click on the DOWNLOAD button above and click on Save
 
3. Once saved, double click 6280_V04.1.54.exe. Extract files to your desktop, or to a directory
of your choice. Once the files are extracted, copy them to the SD card, or extract all files from
6280_V04.1.54.exe directly to the SD card. ALL THE BELOW FILES MUST APPEAR ON
THE ROOT OF THE SD CARD FOR THE UPDATE TO BE SUCCESSFUL
 
4. Take the SD card with the software downloaded and insert it into the slot on upper right side
 of the 6280 Keypad. You will hear a snap when the SD card is inserted correctly.
 (For help locating the SD card slot refer to the image below).
 
5.Now take a paper clip and push in the reset button located on the lower right side of the
keypad. (The Reset button is directly behind the “Message LED on the right side of the plastic.
(For help locating the Reset button refer to the image below).
Once pressed the 6280 Keypad will update the new software. You will see the system/display
reboot which will take about 1 minute.

A message on the screen will appear stating, “REMOVE THE SD CARD AND PRESS OK
TO RESET KEYPAD”. Press ok and your keypad will reboot. As soon as the display comes up
the software update will be complete.

     
    If you don't have a paper clip you can use the tools icon + advanced + reset keypad.

Tuesday, June 9, 2015

5834-4 HIGH SECURITY MODE KEYFOB


 
 
Programming
  • Each 5834-4 transmitter has two unique serial numbers assigned during Loop Numbers for the 5834-4 Buttons manufacture.Each button on the unit also has a distinct "loop" number (refer to the Loop Number at right) that you must program into the control panel during installation.
  • Assign each button to an individual zone and designate the Input Type as "BR" (Button Type).
  • When prompted for the serial number, press and release the appropriate button(s) twice, or, manually enter the serial number at the keypad.
NOTE: Serial #2 is one (1) digit higher than serial #1, which is printed on the rear of the transmitter.
                                                                    Hand Model Cliff S.
USING HIGH SECURITY MODE IN COMPATIBLE RECEIVERS AND LOCALLY IN AN RF KEYPAD (eg., 6150RF) 
If used with LYNXR/Quick Connect Series controls earlier than Revision 13.1, Standard Mode must be selected. First select High Security mode, then activate it. Activation syncs the key fob with the security system.
  • 1. Select High Security mode: Mode Simultaneously hold down for 5 secs… A - C - D (LED flashes Red when transmitting) High-Security B - C - D (LED flashes Green when transmitting) Standard
  • 2. Activate High Security mode: • if the key fob is enrolled into the panel, put the security system into Go/No Go Mode 
  • 3. If the key fob is enrolled locally into a 6150RF, go to Step 3 of 6150RF “Programming WITH Local Wireless Keys”, then press the appropriate set of buttons as follows: Serial Number Simultaneously hold down until beeps sound… A - B - C buttons (system beeps twice to confirm) 1 A - B - D buttons (system beeps twice to confirm)
  •  
    Please see below for instructions provided by our small business team.
    ENTER INSTALLER CODE #8 THEN HOLD ALL THREE BUTTONS (NOT PANIC) AT ONCE AND YOU WILL GET TWO BEEPS. THIS CONCLUDES THE PROGRAMMING

Friday, June 5, 2015

Cheat Sheet For GE Concord Panels


Concord 4 – 4321 (Default)
System Programming: [ 8 ] + [ INSTALLER CODE ] + [ 0 ] [ 0 ]
Select "System Programming"
Security--Global Menu--Downloader Code
Security--Global Menu--Installer Code
Security--Partition1--Account # (repeat/copy for mult partitions)
Security--Partition1--Duress Code (9999)

Phones--CS Phone 1—XXX-XXX-XXXX (repeat/copy for multi partitions)

Phone Options--Global--Auto Phone Test--ON

Timers--Global--Next Phone Test--7
Timers--Global--Phone Test Freq—7 (Weekly)

Reporting--Global--AC Failure--ON
Reporting--Partition1--Duress Option--ON

Sensors--Learn Sensors
Sensors--Sensor Text
Sensors--Delete Sensors (Delete any hardware zones not being used)

To Exit, Select "Exit System Programming"

User Programming: [ 9 ] + [ MASTER USER CODE ]
Set Time/Date
Set Master Code
Set any User Codes

CONCORD System Tests:
COMMUNICATIONS TEST: [ 8 ] + [ MASTER USER CODE ] + [ 2 ]
When the panel completes the test, the system returns to the previous arming level
automatically. If the display continues to show PHONE TEST for 1½ minutes or more, enter [ 1 ] + [ MASTER USER CODE ] and recheck phone connection.

15 min SENSOR TEST: [ 8 ] + [ INSTALLER CODE ] + [ 3 ]
Trip each zone/sensor one at a time. Touchpads (and interior sirens) should sound one short,
high-pitched beep and the display should show the sensor name (or number) and OK.
Press the STATUS button when you think all zones/sensors are tested. The touchpad displays
any untested sensors/zones and touchpad panics. If all sensors/zones and touchpad panics
have been tested, the display shows SENSOR TEST OK.
Exit sensor test [ 1 ] + [INSTALLER CODE ]

REPEAT TESTS FOR MULT PARTITIONS
Turn Partition Security OFF in SECURITY GLOBAL menu, then use 7+4+2 to change partition without using code.
**